Premium sandwich panel room manufacturer and supplier: Settling colony count and plankton determination requirements: at the same time of each experiment, count the settling colony of microorganisms in the operating room and laminar flow table, record the results in the user log, and record the original data of the experimental environment in the experiment report. Disinfection requirements: Every week and every operation in the sterile room, the operating table and the dead corners should be wiped with appropriate disinfectant. The specific method is to use sterile gauze impregnation disinfection solution to clean the entire inner surface of the super clean bench, and aseptic room, flow of people, logistics, buffer room floor, transfer window, door handle. Cleaning and disinfection procedures should be from the inside out, from high clean areas to low clean areas. Gradually exit the clean area. Then turn on the aseptic air filter and UV lamp for 1-2h sterilization to kill the remaining microorganisms. At the end of each operation, wipe the workbench with the above disinfection solution, remove indoor moisture, and sterilize with UV lamp for 30min. Read even more details on sandwich panel room.

The material of the equipment is safe, stable, heat-resistant, and corrosion-resistant. Completely enclosed during production, it will not cause pollution to the outside environment, nor will it be contaminated by the outside environment. The equipment should be easy to clean and preferably have a self-cleaning function. Pharmaceutical equipment has an automatic control system that can systematically control, count, and reduce labor costs. Some drugs have special properties, so it is best for pharmaceutical equipment to have dust-proof, waterproof, and explosion-proof functions. For safety reasons, there should be a one click pause automatic protection equipment.

Because of the different standards and machine styles, the die of tablet press can be divided into single tablet press die and rotary tablet press die. According to different specifications, diameter and tablet shape, the stamping dies of single stamping tablet machine and rotary tablet press can be divided into circular stamping dies and special-shaped stamping dies (triangle, oval, key type, plum blossom, rectangle, etc.), which can be customized according to your needs.

Efficiency of Equipment: Some equipment, such as electronics and mechanical components, require specific humidity levels to function correctly. Maintaining the right humidity levels in clean rooms ensures optimal performance and longevity of these critical pieces of equipment. How to Maintain Optimal Humidity Levels in Clean Rooms? To maintain optimal humidity levels in clean rooms, consider the following steps: Install a Dehumidifier: A dehumidifier is an essential tool for maintaining proper humidity levels in clean rooms. It removes excess moisture from the air, keeping humidity levels within the desired range. Choose a dehumidifier based on the size of your clean room and the relative humidity requirements you need to meet.

The clean room workshop is also called the dust free workshop, gmp cleanroom, the industrial clean room (Clean Room) and the dust free room. It refers to the removal of pollutants such as particles, harmful air and bacteria in the air within a certain space, and the indoor temperature,cleanliness, indoor pressure, air velocity and air distribution, noise and vibration, lighting and static control. A specially designed clean room for a particular requirement. That is to say, no matter how the extemal air conditions change, the clean room can maintain the characteristics of cleanliness temperature and humidity and pressure.

For the unidirectional flow (laminar flow) clean room, the air supply volume is determined by the product of the average wind speed of the room section and the cross-sectional area, in which the measured section of the vertical unidirectional flow (laminar flow) clean room is the horizontal section 0.8m away from the ground; The horizontal unidirectional flow (laminar flow) clean room takes a vertical section 0.5m away from the air supply surface. The spacing of measuring points on the section shall not be greater than 2m, and the number of measuring points shall not be less than 10, which shall be evenly arranged. Hot bulb anemometer for instrument.

Pill stamp press manufacturer and supplier right now: Generally, the air flow distribution point on the surface of the operating table or production equipment should be located at 2/3 of the distance between the clean room space and the partition wall, so that when the operator is working, the air flow can flow from the inside of the process area to the operation area, and the The dust is taken away; if the distribution point is arranged in front of the process area, it will become an improper airflow distribution. At this time, most of the air flow will flow to the process area, and the dust caused by the operator’s operation will be brought to the back of the equipment. As a result, the platform will be polluted, and the yield rate is bound to decrease.

The frame of the clean shed can be generally divided into three types: stainless steel square pass, varnished iron square pass and industrial aluminum profiles. The top and the top can be made of stainless steel steel plate, lacquered cold plastic steel plate, anti-static mesh curtain and acrylic plexiglass and other materials. Anti-static mesh curtains or plexiglass are generally used around, and FFU clean air supply units are used in the air supply unit.

The above introduction is related to the introduction of clean room and testing purpose.If you have different opinions or suggestions, you can always contact us.As long as you want the clean room project, Suzhou Pharma Machinery Co., Ltd. will realize it for you.Choose a reliable engineering company, Suzhou Pharma Machinery Co., Ltd., will be responsible for your project to the end, and the reputation is guaranteed.Our company has completed 500+ clean room projects all over the world. Many new and old customers like to buy the products they want in our company. The price is reasonable, the integrity is guaranteed, and the after-sales service is good.If you have related (clean room) projects recently, you can contact us at any time. See even more details on sz-pharma.com.

Clean room equipment includes air purification equipment and air ventilation equipment. During the construction process, it is necessary to select the appropriate air filtration equipment according to specific practical needs. In general, the selection of air purification equipment will use coupled filtration technology to achieve the purpose of eliminating dust in the air, that is, through multiple layers of different filtration forms, to eliminate foreign particles and harmful substances in the air.